Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0962, Submission # Submission-2017-1002, UID # 10673
Status: Compliance Inspection Accepted
 

System Status

System status on date: 08/08/2017 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
31028214100025676 WOODLANE CT, CITY OF WOODBURY5676WOODLANECTWOODBURYCITY OF WOODBURY55129KOEHNEN RYAN T & STACEY N1979
Owner's representative:
Name:
Tony Canbotom
Phone:
(651592 - 4604
Email:
tonyc@remax.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 3 Decimal Feet
B. Periodically saturated soil/bedrock: 5.3 Decimal Feet
C. System separation: 2.3 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
David R. BrownL3649651-788-3296PO Box 251026 Woodbury, MN 55125NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: drufusb1@yahoo.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2654 (09/27/2017)

Charge Cost Quantity Total
Non-Taxable
added 09/27/2017 8:03 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 09/27/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantDavid R. Brown - 09/27/2017 8:03 AM
faa75a12cd6daf99fe93911d3bc9c70b
e1a991efaff6f5e379afead479cdec35
 
#1 Compliance Inspection AcceptedKati Hallermann - 10/06/2017 10:33 AM
210ecf46668588d7664575f911ba5a99
f527a714cbabb20b9e99000b852c42d4
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by