Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0027, Submission # Submission-2016-0064, UID # 1110
Status: Compliance Inspection Accepted
 

System Status

System status on date: 02/28/2016 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
340292014001215915 HUDSON RD N, TOWN OF WEST LAKELAND15915HUDSONRDNSTILLWATERTOWN OF WEST LAKELAND55082SORTEDAHL NICHOLAS S2017
Property Owner's Mailing Address
(if different than property address):
15971 Hudson BLvd
Lakeland MN 55043
Owner's representative:
Name:
Nicholas Sortedahl
Phone:
(651402 - 7246
Email:
septic@co.washington.mn.us

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 01/01/1990

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
B1 02/17/2016
0-7" Topsoil 10 yr 3/2
7-36" Silt Loam 10yr 4/4
36-78" Med to Course Sand 10yr 5/4
A. Bottom of distribution media: 48 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 24 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1250 gallon pre-cast septic tank and a rock trench gravity drainfield. This septic system is sized for a 3 bedroom home with 450 gallon per day of water useage.
Attach Files:

Certification

Inspector:
Name:
Tom Trooien
MPCA License #:
L1568
Business Name:
All State Septic Service LLC
Phone:
(612594 - 4496
Address:
12020 Square Lake Trail Ct N
Stillwater MN 55082

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #572 (03/04/2016)

Charge Cost Quantity Total
Non-Taxable
added 03/04/2016 8:07 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 03/04/2016$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantNicholas Sortedahl - 03/04/2016 8:09 AM - witnessed by Kati Hallermann
e8dc0a357e9401c1c88458a6ccf87248
1b401044f734134397e9644e06cbe5cc
 
#1 Compliance Inspection AcceptedKati Hallermann - 03/04/2016 8:09 AM
cd28d6373549b163bba1638f693be561
5b3dd02435e26cee42a86dd36d65ad58
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by