Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-1005, Submission # Submission-2017-1056, UID # 11230
Status: System Replaced
 

System Status

System status on date: 10/23/2017 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
31028204200015550 NEAL AVE S, CITY OF AFTON5550NEALAVESAFTONCITY OF AFTON55001GARY L SWANSON REV TRS & LORI A SWANSON REV TRS1870
Owner's representative:
Name:
Barry Nelson
Phone:
(651276 - 8145
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
See Report
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
bwndmn97@aol.com
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2772 (10/27/2017)

Charge Cost Quantity Total
Non-Taxable
added 10/27/2017 3:21 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 10/27/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 10/27/2017 3:21 PM
6abe259453af92b499d4214645f77302
4a28df4f074a1ced4434f3a8e40c16f3
 
#1 Compliance Inspection AcceptedChristopher W. LeClair REHS - 10/30/2017 8:05 AM
1e43a947ae37a843ad5bde64f94ae766
ed8641707225ad3f5c151a8dd0583fdb
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
        Powered by