Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-1040, Submission # Submission-2017-1081, UID # 11413
Status: Compliance Inspection Accepted
 

System Status

System status on date: 10/24/2017 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
040322122000323950 LAKE BLVD N, CITY OF FOREST LAKE23950LAKEBLVDNFOREST LAKECITY OF FOREST LAKE55025KUPPE INVESTMENTS LLC
Owner's representative:
Name:
Michael McElhatton
Phone:
(651462 - 1510
Email:
macsewer12@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)
Comments/Explanation:
No other visible problems observed at the time of inspection.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Tank pumped by Smilie's Pumping Service & deemed a good precast tank

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
Drainfield meets separation requirement and therefore meets compliance.
A. Bottom of distribution media: 12 Decimal Feet
B. Periodically saturated soil/bedrock: 44 Decimal Feet
C. System separation: 32 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
Gravity Mound with Septic Tank.
NOTE: no records found-system is old approx. 37years old & most likely original (1980). Gravity mound CAUTION should be used to avoid overloading or abusing system which could cause failure.
Recommend cutting trees & brush on mound- keep grass established and mowed.
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Mac's Sewer ServicesL1476651-462-151034918 Falcon Ave N North Branch, MN 55056NoNoNoNoNo
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: macsewer12@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2852 (11/17/2017)

Charge Cost Quantity Total
Non-Taxable
added 11/17/2017 9:54 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 11/17/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantMike McElhatton - 11/17/2017 9:54 AM - witnessed by Kati Hallermann
2c177ccbf609d8b80a06e23f68941d3d
3195bb76f09c8175386a35832a548ac6
 
#1 Compliance Inspection AcceptedKati Hallermann - 11/17/2017 9:55 AM
b5c7512c4fcd95295d8485f151ecda14
19d5ab86ee79c1c21a3184d4878bce00
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by