SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-1045, Submission # Submission-2017-1088, UID # 11457
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 11/20/2017 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Comments/Explanation: | No other visible problems observed at the time of inspection |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined construction records Examined empty (pumped) tank(s) |
Comments/Explanation: | Tanks pumped at time of inspection by Ross Sewer Service Precast tanks Approx 1500 & 1000gal septic tanks & 1000gal lift tank (3tanks) |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | Drainfield meets separation requirement & therefore meets compliance |
A. Bottom of distribution media: | 30 Decimal Feet |
B. Periodically saturated soil/bedrock: | 66 Decimal Feet |
C. System separation: | 36 Decimal Feet |
D. Required compliance separation: | 36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | Pressure bed with 1500 & 1000Gal. Septic tanks & 1000Gal. Lift Tank. Note: remove & keep brush and debris off north end of drainfield area where it meets the tree line drainfield runs north/south & north half is being covered with brush & debris which will prevent proper evaporation that is needed for proper function. |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | macsewer12@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #2862 (11/21/2017)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 11/21/2017 10:23 AM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 11/30/2017 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Mac's Sewer Service - 11/30/2017 9:44 AM - witnessed by Kati Hallermann 54d51fc88095079ffa953cd6b8694ca6 442e4663b3a9587488aa093d109a8fe8 | |
#1 Compliance Inspection Accepted | Kati Hallermann - 11/30/2017 9:44 AM 996c2b8f1d5b633d89849e71c0674bd1 1d989e633fccc78fdd97c685d43354d6 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | From: Mike McElhatton [mailto:macsewer12@gmail.com] Sent: Monday, November 20, 2017 9:17 PM To: Dave Bowen <gowhitebear@gmail.com> Cc: Kati Hallermann <Kati.Hallermann@co.washington.mn.us> Subject: 4874-120TH ST-SEPTIC CERT Septic certification & paid receipt attached. Note to Kati--I will pay $40 report fee online & send you confirmation tomorrow. -- Mike McElhatton Mac's Sewer Service 651-462-1510 Designer-Inspector MPCA 1476 |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |