SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1085, Submission # Submission-2017-1119, UID # 11739
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 12/13/2017 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | See Report |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
Yes |
Sewage tank(s) leak below their designed operating depth: |
Yes |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | See Report |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
Explain: | See Report |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Explain: | See Report |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Not applicable (Holding tank(s), no drainfield) |
Comments/Explanation: | See Report |
A. Bottom of distribution media: | 0 Decimal Feet |
B. Periodically saturated soil/bedrock: | 0 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 0 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See Report |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | brian@midwestsoiltesting.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #2946 (12/15/2017)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 12/15/2017 2:37 PM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 12/15/2017 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Brian Humpal - 12/15/2017 2:37 PM 11f58930c43975d43840a3ba6f9722ff e7368aebc1bad3ec4c4da4b71e3ebb07 | |
#1 Compliance Inspection Accepted | Christopher W. LeClair REHS - 01/05/2018 8:48 AM 90dfcfda0799444b8c0a4268c4a15380 bc471a7edc577040693c78cf9a9b5603 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | Don Abbott - 651-249-1445. Looking to abandon the system. He bought property with intent to tear down the cabin as it is only a few feet away from water. He does not have immediate plans to replace or rebuilt. He asked me to email him djabbott1505@gmail.com - over system abandonment permit & reporting form. 6/24(SB) Don is now planning to apply for installation permit within 2 weeks and will wait to abandon the system then. Recommended him to discuss it within the installation contractor as they will have the appropriate equipment onsite when they install the system. |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |