SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1281, Submission # Submission-2018-1305, UID # 15324
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 05/17/2018 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Out let baffle and pipe was solid roots, meaning the tank is not sealed tight |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Unable to verify (See Comments/Explanation) |
Comments/Explanation: | There are no record on this home. Built in 1982. I found the tank and drop box but the system is too deep to find the drainfield. In the drop box the liquid level was 46" deep which means the bottom of rock if there is any would be 58" which would require 82" to verify soil and I am unable to go that deep. So drainfield is unfindable. |
A. Bottom of distribution media: | 58 Decimal Feet |
B. Periodically saturated soil/bedrock: | 0 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | Septic tank going to one drop box. Unable to find anymore drainfield because it is too deep in the ground. |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | arkseptic@gamil.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #3309 (05/30/2018)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 05/30/2018 9:42 AM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 06/15/2018 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Ashley Krause-Ark Septic - 06/15/2018 2:28 PM - witnessed by Kati Hallermann 41a38d89fade8f536580fa0b2f2b2d1c 51b33ded996ed4b465d32e33fd15f130 | |
#1 Compliance Inspection Accepted | Tyler Dale - 06/15/2018 2:32 PM 7912f10a8bdcbd2653ea62c1a789178c c7834ccb7832d74933df9fa66ac3ce39 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |