Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1281, Submission # Submission-2018-1305, UID # 15324
Status: System Replaced
 

System Status

System status on date: 05/17/2018 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
020282031000816440 7TH STREET LN S, CITY OF LAKELAND164407TH STREETLNSLAKELANDCITY OF LAKELAND55043CARLSON COREY31JACKSON FARM1982
Owner's representative:
Name:
Ashley Krause
Phone:
(763760 - 4172
Email:
arkseptic@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Out let baffle and pipe was solid roots, meaning the tank is not sealed tight

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Unable to verify (See Comments/Explanation)
Comments/Explanation:
There are no record on this home. Built in 1982. I found the tank and drop box but the system is too deep to find the drainfield. In the drop box the liquid level was 46" deep which means the bottom of rock if there is any would be 58" which would require 82" to verify soil and I am unable to go that deep. So drainfield is unfindable.
A. Bottom of distribution media: 58 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 36 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
Septic tank going to one drop box. Unable to find anymore drainfield because it is too deep in the ground.
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Ark Septic LLCL3974763-257-4378PO Box 229 Zimmerman, MN 55398NoYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: arkseptic@gamil.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #3309 (05/30/2018)

Charge Cost Quantity Total
Non-Taxable
added 05/30/2018 9:42 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 06/15/2018$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantAshley Krause-Ark Septic - 06/15/2018 2:28 PM - witnessed by Kati Hallermann
41a38d89fade8f536580fa0b2f2b2d1c
51b33ded996ed4b465d32e33fd15f130
 
#1 Compliance Inspection AcceptedTyler Dale - 06/15/2018 2:32 PM
7912f10a8bdcbd2653ea62c1a789178c
c7834ccb7832d74933df9fa66ac3ce39
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance: