Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1365, Submission # Submission-2018-1409, UID # 16093
Status: System Replaced
 

System Status

System status on date: 07/23/2018 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Other Compliance Conditions (Compliance Component #3) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
290282022000813201 40TH ST S, CITY OF AFTON1320140THSTSAFTONCITY OF AFTON55001BELKNAP JODIE R & BARBARA J DACY1977
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)
System requires "emergency" pumping

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
Yes
Explain:
Drainfield no longer accepts effluent, necessitating emergency pumping of the septic tank.

Date of Install

Date of install known: Yes
Date of installation: 07/23/1976

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Other (See Comments/Explanation)
Comments/Explanation:
Soil testing is not needed because it was done 9/16/2015 and is still valid. A design for a replacement system is underway as of 7/23/2018.
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #3528 (07/23/2018)

Charge Cost Quantity Total
Non-Taxable
added 07/23/2018 7:41 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 07/23/2018$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 07/23/2018 7:42 PM
ed83c744ba88e6932fdfc6cda7d80746
3e0e1e2a93ca4e254488c39cdf3fbf69
 
#1 Compliance Inspection AcceptedTyler Dale - 08/08/2018 2:46 PM
74be9e4e9de95d925ddf6c790d5ce212
c9a1685a75d1e23309629f391623f932
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    I called Tom to see what the deal with this compliance inspection was. Said the owners had a leaky toilet they did not fix for 6 months. This overloaded the system, and the system will no longer take effluent. They are pumping the tank ~ every 2 weeks. In 2015 Brian Humple conducted a compliance inspection, Tom relied on his soils work. Tom also said that they are getting a loan through the county and needed documentation that it was failing, hence the reason for the compliance inspection.
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance: