SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1394, Submission # Submission-2018-1445, UID # 16530
Status: Permit Issued
Status: Permit Issued
System Status
System status on date: | 08/08/2018 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Homeowner testimony (See Comments/Explanation) |
Comments/Explanation: | Nothing Else Observed at the time of Inspection |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined construction records Examined empty (pumped) tank(s) |
Comments/Explanation: | Tank pumped by Olson's sewer svs at time of inspection, good 1250 gal septic tank- maybe reused subject to new drainfield design, layout & sizing factors missing inlet baffle to be replaced by Olson's sewer |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Other (See Comments/Explanation) |
Comments/Explanation: | Drainfield does not meet compliance & must be replaced to bring into compliance |
A. Bottom of distribution media: | 42 Decimal Feet |
B. Periodically saturated soil/bedrock: | 16 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 24 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | Gravity trench with 1250 gal septic tank. Drainfield does not have the vertical separation required for the proper treatment of wastewater per MPCA ch 7080 must be replaced to bring system into compliance |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | macsewer12@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #3605 (08/13/2018)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 08/13/2018 3:28 PM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 08/13/2018 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Micheal McElhatton- Mac Sewer - 08/16/2018 4:06 PM - witnessed by Kati Hallermann 5641a2bcf1925a704a70ca1c8b6b0144 0d574b69b914aad85126b381875b4c79 | |
#1 Compliance Inspection Accepted | Tyler Dale - 08/16/2018 4:06 PM 87c4f3090f1b09d57c5499f5768807ab 0ec11450c4a18e14117f6ab958269fbb |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | The property owner has requested an extension for replacing system. |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Tyler Dale | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |