Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1394, Submission # Submission-2018-1445, UID # 16530
Status: Permit Issued
 

System Status

System status on date: 08/08/2018 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
120302143000211855 102ND STREET CT N, CITY OF GRANT11855102ND STREETCTNSTILLWATERCITY OF GRANT55082JOHNSON EDWIN H & KATHLEEN J23RED HAWK RIDGE1984
Owner's representative:
Name:
Michael McElhatton
Phone:
(651462 - 1510
Email:
macsewer12@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)
Comments/Explanation:
Nothing Else Observed at the time of Inspection

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined construction records
Examined empty (pumped) tank(s)
Comments/Explanation:
Tank pumped by Olson's sewer svs at time of inspection, good 1250 gal septic tank- maybe reused subject to new drainfield design, layout & sizing factors missing inlet baffle to be replaced by Olson's sewer

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Other (See Comments/Explanation)
Comments/Explanation:
Drainfield does not meet compliance & must be replaced to bring into compliance
A. Bottom of distribution media: 42 Decimal Feet
B. Periodically saturated soil/bedrock: 16 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
Gravity trench with 1250 gal septic tank.
Drainfield does not have the vertical separation required for the proper treatment of wastewater per MPCA ch 7080 must be replaced to bring system into compliance
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Mac's Sewer ServicesL1476651-462-151034918 Falcon Ave N North Branch, MN 55056NoNoNoNoNo
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: macsewer12@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #3605 (08/13/2018)

Charge Cost Quantity Total
Non-Taxable
added 08/13/2018 3:28 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 08/13/2018$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantMicheal McElhatton- Mac Sewer - 08/16/2018 4:06 PM - witnessed by Kati Hallermann
5641a2bcf1925a704a70ca1c8b6b0144
0d574b69b914aad85126b381875b4c79
 
#1 Compliance Inspection AcceptedTyler Dale - 08/16/2018 4:06 PM
87c4f3090f1b09d57c5499f5768807ab
0ec11450c4a18e14117f6ab958269fbb
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    The property owner has requested an extension for replacing system.
    File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by