SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1609, Submission # Submission-2019-1659, UID # 20712
Status: Permit Issued
Status: Permit Issued
System Status
System status on date: | 03/25/2019 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Impact on Public Health (Compliance Component #1) - Imminent threat to public health and safety |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
Yes | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | The end of the seepage bed is exposed and is discharging effluent to the ground surface. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Lowered underwater camera into tanks- baffles and tank walls OK. Lift pump and alarm were operational at the time of the inspection. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) Other (See Comments/Explanation) |
A. Bottom of distribution media: | 27 Decimal Feet |
B. Periodically saturated soil/bedrock: | 60 Decimal Feet |
C. System separation: | 33 Decimal Feet |
D. Required compliance separation: | 36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | Property owner email: snelling@outlook.com |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | brian@midwestsoiltesting.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #4144 (03/26/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 03/27/2019 3:48 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 03/27/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Brian Humpal - 03/27/2019 3:48 PM ba6cea57b20964a90dc924af6550b857 1d852b6fd818d9ae8aa40e5a026af2f4 | |
#1 Compliance Inspection Accepted | Joe Sanders - 04/03/2019 1:17 PM 90c216d23c477d75c03eb8dd4d8e4abc 4962957f845b109e3503f4330bcbd2ee |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | Talked with the home owner 4/15/19. System has been pumped and is currently not in use. The system is going to be abandoned and then hooked up to Afton's sewer. |
File(s): |
Compliance Letter Type: | Imminent Threat, Abatement Notice and Order | Who's signature should be on the letter? | Tyler Dale | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |