Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1638, Submission # Submission-2019-1703, UID # 20911
Status: System Replaced
 

System Status

System status on date: 04/24/2019 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
21030201100022318 BOOM RD, CITY OF STILLWATER2318BOOMRDSTILLWATERCITY OF STILLWATER55082LEY GREGORY1888
Owner's representative:
Name:
Craig Messner
Phone:
(123456 - 7890
Email:
noemail@email.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Homeowner testimony (See Comments/Explanation)
Comments/Explanation:
A cesspool, a pre-cast septic/lift tank, and a rock trench drainfield. It should be noted that the drainfield is located in a city easement.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Probed tank(s) bottom
Examined construction records
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Although not compliance criteria, it should be noted that the septic tank inlet baffle is missing. Lift pump and alarm were operational at the time of the inspection.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
Installation year: 1997

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
Soil Boring 1:
10YR 2/2 Sandy Loam w/ Gravel, 15-25% Sandstone Fragments (0"-34")
10YR 4/6 Loamy Sand (34"-50")
7.5YR 4/3 Silt Loam, Saturated to Moist (50"-57")
7.5YR 4/3 Silt Loam w/ 7.5YR 5/8 Redox (57"-63")
Refusal at 63"- Sandstone? (Bedrock)
A. Bottom of distribution media: 3 Decimal Feet
B. Periodically saturated soil/bedrock: 4.75 Decimal Feet
C. System separation: 1.75 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4233 (04/25/2019)

Charge Cost Quantity Total
Non-Taxable
added 04/26/2019 4:10 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 04/26/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 04/26/2019 4:10 PM
1691769d50f9f6e10e664c67fad3e998
879e584b6eac384a29d1d985489a472b
 
#1 Compliance Inspection AcceptedTyler Dale - 05/02/2019 8:44 AM
bdb2d6cf2824ffcbba83af3cd6f46dea
de776080f15e02cfb9132afe8acef619
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance: