Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1808, Submission # Submission-2019-1902, UID # 22660
Status: System Replaced
 

System Status

System status on date: 07/22/2019 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
010322123000623545 JENSEN AVE N, CITY OF FOREST LAKE23545JENSENAVENFOREST LAKECITY OF FOREST LAKE55025FRENCH BILLY J54HUNTER'S HILL1988
Owner's representative:
Name:
Billy French
Phone:
(123456 - 7890
Email:
noemail@email.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Homeowner testimony (See Comments/Explanation)
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
At the time of my inspection, I observed lush and very dark green grass growing over the first trench of the drainfield. This may be an indicator that the drainfield may be at the end of its useful life. In addition, the drainfield is sized for a three bedroom house, the house is now a four bedroom house and is undersized by approximately 144 feet.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Probed tank(s) bottom
Examined construction records
Observed liquid level below operating depth
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Pumper indicated a crack in bottom of the septic tank.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 09/23/1988

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
Reviewed design and permit records.
A. Bottom of distribution media: 1.8 Decimal Feet
B. Periodically saturated soil/bedrock: 3.8 Decimal Feet
C. System separation: 2 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4634 (07/23/2019)

Charge Cost Quantity Total
Non-Taxable
added 07/26/2019 9:31 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 07/31/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 07/26/2019 9:31 AM
ed81d380c0caab7f913e8e40e3ca8811
cb20aa57ce3cd8245ea42c0e58e87eaf
 
#1 Compliance Inspection AcceptedPaul O'Neel - 08/01/2019 10:10 AM
4b92b798d650ba9b572081ee320e05b3
baa5a811295fc792bc5079839af5cb24
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by