SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1867, Submission # Submission-2019-1936, UID # 23172
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 08/06/2019 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Although not a compliance criteria, it should be noted that gravelless pipe is no longer approved for installation in the State of Minnesota and we have had experience with this product having significantly reduced performance and/or life expectancy. We cannot guarantee the performance of this system beyond the compliance date (8/6/2019). |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Lowered underwater camera into tanks - baffles and tank walls OK. Lift pump and alarm were operational at the time of the inspection. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 01/01/2003 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 1.58 Decimal Feet |
B. Periodically saturated soil/bedrock: | 3.3 Decimal Feet |
C. System separation: | 1.7 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See Report |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | brian@midwestsoiltesting.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #4717 (08/13/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 08/14/2019 4:34 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 08/16/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Brian Humpal - 08/14/2019 4:34 PM 4794cd4a56162377e63601f65a27481e fee1352f641649e401048d32f73ac9d1 | |
#1 Compliance Inspection Accepted | Barbara Pena - 08/28/2019 12:59 PM 43bdcd607e01df1825b3f3ac26f9bcb7 b7cd1f1ea504aaa17b752d10755072f4 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | 08/26/2019: Spoke with Michael Boston at 11:49a.m. Michael explained a compliance inspection was done on his septic system that came back non-compliant. We spoke about city sewer and the county would consider this if the City of Lake Elmo could provide a timeline for installation. Michael was concerned with spending money for septic system and then city sewer comes through the neighborhood. Michael said he has a design, J. Kloeppner, and an installer, Brian Humpal, lined up to do the work. PMO |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Barbara Pena | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |