Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1894, Submission # Submission-2019-1951, UID # 23359
Status: System Replaced
 

System Status

System status on date: 05/02/2019 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
33027213200128251 RIVER ACRES RD S, CITY OF COTTAGE GROVE8251RIVER ACRESRDSCOTTAGE GROVECITY OF COTTAGE GROVE55016ZIEBA JEFFREY L & BRONWEN J MORGAN13HOUSE'S RIVER ACRES1962
Property Owner's Mailing Address
(if different than property address):
8251 River Acres Road S
Cottage Grove MN 55016
Owner's representative:
Name:
Shelley L Schlomka
Phone:
(651438 - 6866
Email:
sssepticsolutions@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
The system does not have a precast water tight tank and we were not able to locate exact location of drain field.  System needs to be brought up to code. pumped 1000 gallons through 4"pipe. Tank not watertight. Systems needs to be updated. 5-2-19

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
Tank is being pumped through a hole cut out of the deck.  Tank is under deck and pumping out of pipe not man hole.
System is non protective of groundwater for other
conditions as determined by the inspector:
Yes
Explain:
Tank is not water tight.  It has a dirt bottom and drain field unknown.

Date of Install

Date of install known: Yes
Date of installation: 06/01/1962

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2 Decimal Feet
B. Periodically saturated soil/bedrock: 5 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
D. Schlomka Inc.L1106320-384-791141788 Fleming Logging Rd Hinckley, MN 55037NoYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: sssepticsolutions@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4749 (08/20/2019)

Charge Cost Quantity Total
Non-Taxable
added 08/20/2019 7:29 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 08/20/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantShelley L. Schlomka - 08/28/2019 6:24 PM
75a23a6a7523cd63a246275277cd272e
40ec3302bf9b98a635bdaf0e46912203
 
#1 Compliance Inspection AcceptedBarbara Pena - 09/12/2019 10:56 AM
cfbaf0385e7abe2a7e15c37caf7d8869
a32ce75092e191361675c79e27dda042
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Barbara Pena Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: