Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1933, Submission # Submission-2019-2021, UID # 24033
Status: System Replaced
 

System Status

System status on date: 09/24/2019 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
14030213200049380 KESWICK AVE N, CITY OF GRANT9380KESWICKAVENSTILLWATERCITY OF GRANT55082ALTON BROCK & LARINA21LAKE MASTERMAN ESTATES 2ND ADD1994
Owner's representative:
Name:
Nikki Martindale
Phone:
(123456 - 7890
Email:
noemail@email.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Lowered underwater camera into tanks - baffles and tank walls OK.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
Septic Installed: 1993

0-10 inches: 10YR 3/3 Loamy Sand
10-24 inches: 10YR 4/3 Loamy Sand
24-36 inches: 10YR 4/3 Loamy Sand With 7.5YR 7/2 & 7.5YR 5/8 Redox
A. Bottom of distribution media: 2.3 Decimal Feet
B. Periodically saturated soil/bedrock: 2 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4886 (09/25/2019)

Charge Cost Quantity Total
Non-Taxable
added 09/27/2019 11:22 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 09/27/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 09/27/2019 11:22 AM
fb6e7f308f515b72909c0aec15ee18f1
d54f42b0bf86763e1226d16c83a39474
 
#1 Compliance Inspection AcceptedPaul O'Neel - 10/04/2019 2:47 PM
07e9e36300c5308e59bc89b30f2907ad
f54fb2ebee96e52a6e0fe68fb36380b3
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    10-01-2019: Ryan Martindale, 612-770-2519, owner of property left me a message. Ryan was looking to find out the status of the recent compliance inspection conducted on the SSTS. I returned his call 10/03/19 @ 9:00a.m. Left message for him to call me back. PMO
    10-04-2019: Received call from Ryan Martindale at 2:00p.m. Ryan questioned whether the County would "grandfather" the existing system on his property since this was done in 2014. I told Ryan that would not be possible and the system would need to be repaired, replaced, or abandoned. I sent Ryan information on septic contractors and told him to start making calls to see if a designer would be available to design a new system. PMO
    File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by