Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1943, Submission # Submission-2019-2026, UID # 24146
Status: Compliance Inspection Accepted
 

System Status

System status on date: 09/20/2019 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
26029204200171443 OLD TOLL BRIDGE RD N, CITY OF LAKELAND1443OLD TOLL BRIDGERDNLAKELANDCITY OF LAKELAND55043MARTIN HARRY L & CECILIA J1973
Property Owner's Mailing Address
(if different than property address):
1443 Old Toll Bridge Road
Lakeland MN 55043
Owner's representative:
Name:
Harry Martin
Phone:
(651303 - 2264
Email:
alex.pepin@tenthirtyenvironmental.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)
Comments/Explanation:
Septic tank does not have baffles in place.  While the tank is water tight and meets compliance criteria baffles should be added (especially outlet baffle) or the tank replaced to ensure solids are not going to the pump tank and being pumped out to the soil treatment area and reducing the life of the system.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Dropped underwater camera into tanks and observed no cracks in either pump tank or septic tank and the liquid level at the outlet invert of the septic tank (see attached picture).  No baffles are on the septic tank and this should be remedied, although it is not a compliance criteria

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
meets required separation.

Date of Install

Date of install known: Yes
Date of installation: 06/01/1989

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
System has 3.27 feet of separation from bottom of media to restriction.
A. Bottom of distribution media: 97.36 Decimal Feet
B. Periodically saturated soil/bedrock: 94.09 Decimal Feet
C. System separation: 3.27 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Ten Thirty Environmental Solutions, SBCL4082612-248-42811684 132nd Ave NE Blaine, MN 55449NoNoYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: alex.pepin@tenthirtyenvironmental.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4903 (09/30/2019)

Charge Cost Quantity Total
Non-Taxable
added 09/30/2019 9:20 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 09/30/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantAlex Pepin - 09/30/2019 9:20 AM
af8977e8fb91f4bebcdc0765b2acaf96
6632ff747043619cc4843ef1afa059c1
 
#1 Compliance Inspection AcceptedKati Hallermann - 10/14/2019 7:31 AM
f36697a2e907baffe2bf35338b17027a
68d0ebca9b550c0e541b9a18c5d24e8b
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance: