SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1966, Submission # Submission-2019-2046, UID # 24231
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 10/03/2019 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes Homeowner testimony (See Comments/Explanation) |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Lowered underwater camera into tanks - baffles and tank walls OK. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | Septic installed: 1977 Soil observation: 0-13 inches: 10YR 3/3 Silt Loam 13-18 inches: 10YR 4/3 Clay Loam With 7.5YR 5/8 & 10YR 6/2 Redox 18-30 inches: 10YR 3/4 Very Medium Coarse Sand 30-38 inches: 10YR 4/4 Medium Sand 38-44 inches: 7.5YR 3/4 Sandy Loam 44-60 inches: 7.5YR 3/4 Sandy Loam With 7.5YR 5/8 & 10YR 6/2 Redox |
A. Bottom of distribution media: | 3 Decimal Feet |
B. Periodically saturated soil/bedrock: | 1.1 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | brian@midwestsoiltesting.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #4930 (10/04/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 10/09/2019 3:47 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 10/11/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Brian Humpal - 10/09/2019 3:47 PM 19eeb3c2282a0bc23003140164a4dbb8 6d13fdce9a855fdf6394ee998a497b8a | |
#1 Compliance Inspection Accepted | Paul O'Neel - 10/15/2019 11:00 AM 963b44417eac0088383b17211f80d50e 5da736846d3c878373cf11c878b2b2e0 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Paul O'Neel | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |