SSTS Permitting
Compliance Inspection Compliance Inspection Submission # Submission-2019-2117, UID # 25441
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 12/02/2019 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
Yes |
Sewage tank(s) leak below their designed operating depth: |
Yes |
Verification method(s): | Examined construction records Examined empty (pumped) tank(s) |
Comments/Explanation: | Dropped camera down in dry tanks (owner passed away earlier in the year). Observed numerous cracks and tree roots in both tanks below the operating level. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Other (See Comments/Explanation) |
Comments/Explanation: | No drainfield |
A. Bottom of distribution media: | 0 Decimal Feet |
B. Periodically saturated soil/bedrock: | 0 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 0 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | System consists of a septic tank followed by a cesspool. No drainfield was found and permit record indicates a permit was applied for in 1976 but the permit expired as noted by inspector on 3/4/1980. System non-compliant and design is scheduled for the spring when the snow is off. |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | alex.pepin@tenthirtyenvironmental.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #5096 (12/03/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 12/03/2019 2:24 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 12/03/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Alex Pepin - 12/03/2019 2:24 PM 268fbb1d929228473b762260e142aee5 c08a8cc88c7c0015d640bbc868bd876a |
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Cesspool | Who's signature should be on the letter? | Barbara Pena | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |