Compliance Inspection Compliance Inspection Submission # Submission-2020-2191, UID # 27177
Status: System Replaced
 

System Status

System status on date: 03/16/2020 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Other Compliance Conditions (Compliance Component #3) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
0202820120014145 ST CROIX TRL S, CITY OF LAKELAND SHORES145ST CROIXTRLSLAKELANDCITY OF LAKELAND SHORES55043NKM INC72CENTURY PARKNo
Owner's representative:
Name:
Craig Armstrong
Email:
craig@craigarmstronghomes.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Probed tank(s) bottom
Examined construction records
Probed outside tank(s) for "black soil"
Comments/Explanation:
South Tank Appears to be sand bottom based on probing tank bottom- Deep tank (>5'). North Tank needs to be pumped to verify.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
Yes
Explain:
NO ALLOWABLE TREAMENT BEYOND 7' AS PER MPCA 7080.2150 SUBP 3 c2, SOUTH DRAINFIELD 7' DEEP THEREFORE NONCOMPLANT- UNABLE TO LOCATE NORTH DRAINFIELD, LIKELY BENEATH GARAGES. SOUTH
DRAINFIELD LIKELY BENEATH PARKING LOT/DRIVEWAY.

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Unable to verify (See Comments/Explanation)
Comments/Explanation:
NO ALLOWABLE TREAMENT BEYOND 7' AS PER MPCA 7080.2150 SUBP 3 c2, SOUTH DRAINFIELD 7' DEEP THEREFORE NONCOMPLANT- UNABLE TO LOCATE NORTH DRAINFIELD, LIKELY BENEATH GARAGES. SOUTH DRAINFIELD LIKELY BENEATH PARKING LOT/DRIVEWAY.
A. Bottom of distribution media: 6 Decimal Feet
B. Periodically saturated soil/bedrock: 7 Decimal Feet
C. System separation: 1 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
TWO SYSTEMS ON THE PROPERTY. SOUTH TANK IS VERY DEEP >5', PROBED BOTTOM AND APPEARS TO BE SAND BOTTOM TANK. NORTH TANK APPEARS PRECAST AND MAY BE COMPLIANT HOWEVER NEEDS TO BE DUG UP AND PUMPED TO VERIFY (36" DEEP). UNABLE TO LOCATE NORTH DRAINFIELD. SOUTH DRAINFIELD APPEARS TO BE BENEATH THE PARKING LOT/DRIVEWAY, NORTH DRAINFIELD MAY BE BENEATH DETACHED GARAGE.
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Lashinski SepticL65763-434-39151244 Crosstown Blvd NE Ham Lake, MN 55304NoNoNoNoNo
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: rlashinski@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #5320 (03/16/2020)

Charge Cost Quantity Total
Non-Taxable
added 03/16/2020 1:17 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 03/16/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantRyan E. Lashinski - 04/15/2020 1:09 PM
ec4edd328480d67fe1adfcd0b3133b3b
9586fd8a29e288951a6263c8e702721f
 
Text:
File(s):
Text:
contacted Compliance Inspector/ applicant to request applicant approval/ signature to process the  report on 4/13/20. BP
File(s):
Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Barbara Pena Permit number to reference in "No Replace" letter:
Was the letter sent? Yes Compliant/Non-Compliant:
Certificate of Compliance:
    Letter of Non-Compliance:
      Powered by