Compliance Inspection Compliance Inspection Compliance Inspection # CI-2020-2131, Submission # Submission-2020-2209, UID # 27274
Status: System Replaced
 

System Status

System status on date: 03/25/2020 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
290322041001112070 LAKAMAGA TRL N, CITY OF SCANDIA12070LAKAMAGATRLNMARINE ON ST CROIXCITY OF SCANDIA55047CHRISTINE E AITA TOMPKINS REV TRS1971
Owner's representative:
Name:
Lorraine pratt
Phone:
(123456 - 7890
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
"Black soil" above soil dispersal system
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Although not a compliance criteria, it should be noted that a soil boring adjacent to the mound rock bed indicated ponding. This is an indication that the mound may be at the end of its useful life. In addition, there is water infiltration into the septic tank and lift tank.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Lift pump and alarm were operational at the time of the inspection.
n addition, there is water infiltration into the septic tank and lift tank. ponding.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No
Date of installation: 01/01/1971

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
A. Bottom of distribution media: 2.9 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 1.5 Decimal Feet
D. Required compliance separation: 36 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #5348 (03/27/2020)

Charge Cost Quantity Total
Non-Taxable
added 03/27/2020 3:55 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 03/27/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 03/27/2020 3:55 PM
c8e36c5d70a422e49d63dd8c88041ab1
d7e7a0a654c8b3ba0478d07977719b9b
 
#1 Compliance Inspection AcceptedBarbara Pena - 04/16/2020 11:27 AM
427c5d5a265995d060aa72bf9e02c6fd
cda62beb29161fd2135ec2ae34758f40
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Barbara Pena Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by