Compliance Inspection Compliance Inspection Compliance Inspection # CI-2020-2134, Submission # Submission-2020-2221, UID # 27319
Status: System Replaced
 

System Status

System status on date: 03/31/2020 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
15030203100029198 ST CROIX TRL N, TOWN OF STILLWATER9198ST CROIXTRLNSTILLWATERTOWN OF STILLWATER55082SENALL JEFFREY A & ELIZABETH WOLF-SENALL1957
Owner's representative:
Name:
Ken Wolf
Phone:
(651308 - 5968
Email:
info@wolfmarine.net

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Comments/Explanation:
Borings above the trenches did show they are all seeing water and the system could be reaching the end of its useful life.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
Yes
: Only one tank
Verification method(s):
Probed tank(s) bottom
Examined construction records
Observed liquid level below operating depth
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Crack seen in tank during inspection around outlet and operating below operating level. Dropped camera in as well

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/01/1977

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 87.86 Decimal Feet
B. Periodically saturated soil/bedrock: 86.47 Decimal Feet
C. System separation: 1.39 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
Even in sand the borings above all the trenches showed they were all seeing water and the system is probably reaching the end of its useful life. Non-compliant due to failure to protect groundwater (<2' of separation from trenches and crack in tank).
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Ten Thirty Environmental Solutions, SBCL4082612-248-42811684 132nd Ave NE Blaine, MN 55449NoNoYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: alex.pepin@tenthirtyenvironmental.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #5383 (04/07/2020)

Charge Cost Quantity Total
Non-Taxable
added 04/07/2020 9:28 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 04/07/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantAlex Pepin - 04/07/2020 9:28 AM
fa243144a81f32a4c7a780999b364430
15af3b0bff831236e325443db4733ef4
 
#1 Compliance Inspection AcceptedBarbara Pena - 04/20/2020 4:05 PM
b4ae9e4e59e3ad660a4ca575671f369c
fa9cf8d0505226fb1c19231e944c459a
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by