Compliance Inspection Compliance Inspection Submission # Submission-2020-2236, UID # 27366
Status: System Replaced
 

System Status

System status on date: 04/11/2020 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Impact on Public Health (Compliance Component #1) - Imminent threat to public health and safety

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
03029212400089576 55TH ST N, CITY OF LAKE ELMO957655THSTNLAKE ELMOCITY OF LAKE ELMO55042MIDTHUN CARL T & ALINA M22JUDITH MARY MANOR1997
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
Yes System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Comments/Explanation:
Portions of gravel-less drainfield pipe are saturated, exposed and discharging sewage to the ground surface

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Comments/Explanation:
The outlet baffle on the second tank is deteriorating

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 08/01/1997

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
0-8 inches: Sandy loam 10YR 3/3
8-24 inches: Sandy loam 10YR 3/6
24-40 inches: Loamy sand 10YR 3/4
40-60 inches: Sandy loam 10YR 4/4
A. Bottom of distribution media: 1.5 Decimal Feet
B. Periodically saturated soil/bedrock: 5 Decimal Feet
C. System separation: 3.5 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #5401 (04/11/2020)

Charge Cost Quantity Total
Non-Taxable
added 04/11/2020 7:56 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 04/11/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 04/11/2020 7:56 AM
1475084c32bce0b9e7d1031ef740e1a3
e7fc8d83b7a48dff5a1e5883eb39f696
 
Text:
File(s):
    Text:
    04-24-2020: Forwarded email conversation from Gary Bruns regarding failed system. Refer to email. PMO
    File(s):
    Compliance Letter Type: Imminent Threat, Abatement Notice and Order Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by