SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2020-2186, Submission # Submission-2020-2297, UID # 28106
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 05/27/2020 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records Examined Tank Integrity Form (Attach) |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
Yes |
Date of Install
Date of install known: | Yes |
Date of installation: | 09/07/2004 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | 1-6" top soil 10 yr 2/2 loam,6-22" 7.5 yr 3/2 sandy loam , 22-24" lime rock ,end of bore mound with 18" sand |
A. Bottom of distribution media: | .18 Decimal Feet |
B. Periodically saturated soil/bedrock: | .22 Decimal Feet |
C. System separation: | .4 Decimal Feet |
D. Required compliance separation: | .36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | bfsbob1@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #5566 (05/29/2020)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 05/29/2020 3:57 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 05/29/2020 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Bob Freiermuth - 05/29/2020 3:57 PM f6d4e8a313359efd21015e8593fd0f9b 685869cd268a29c0fc2831f8ca803ae0 | |
#1 Compliance Inspection Accepted | Denise Lange - 05/29/2020 4:27 PM 69e8892a1aed81437ce34c6c3582bc28 90f1e2f5735e116bda17a8c63d308598 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |