SSTS Permitting
Compliance Inspection Compliance Inspection Submission # Submission-2020-2322, UID # 28349
Status: Replacement Extension Granted
Status: Replacement Extension Granted
System Status
System status on date: | 06/17/2020 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes Homeowner testimony (See Comments/Explanation) |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined construction records |
Comments/Explanation: | The tank is at normal operating level |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 07/19/1988 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 2 Decimal Feet |
B. Periodically saturated soil/bedrock: | 1.7 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | tomtrooien@aol.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #5642 (06/17/2020)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 06/17/2020 9:13 AM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 06/17/2020 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Tom Trooien - 06/17/2020 9:13 AM 04982204745b96b9b9d1d572471e2eef 5bcc98a1046f3327c8ba453e67cd164a |
Text: | |
File(s): |
Text: | 06-25-2020: The Department spoke with Cheryl Streit. Extension is granted until City of Woodbury determines feasibility of city water/sewer in this area of the City. Email attached. PMO 06-26-2020: Extension granted. Letter emailed to Cheryl Streit. PMO 07-24-2020: Spoke to Justin(651-402-3007) at Edina Realty at 8:41a.m. Justin called to determine status of city water/sewer services in area of Woodbury. We discussed that the County issued an extension for replacement until Woodbury determines feasibility of running city services in this area. Justin stated he was going to contact Woodbury to see if additional information was available. PMO 09-24-2020: Spoke with Jody at Edina Realty, 651-702-5907. Informed her of the extension letter. TLD |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Paul O'Neel | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |