Compliance Inspection Compliance Inspection Compliance Inspection # CI-2020-2314, Submission # Submission-2020-2453, UID # 29995
Status: Compliance Inspection Accepted
 

System Status

System status on date: 08/21/2020 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
35030212300116575 KEATS AVE N, CITY OF GRANT6575KEATSAVENSTILLWATERCITY OF GRANT55082SANETRA JESSE11INDIAN HILLS 2ND SUBD1979
Owner's representative:
Name:
Cheryl Stinski
Phone:
(612518 - 5207
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
"Black soil" above soil dispersal system

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
: See attached tank integrity report by Olson's Sewer Service MH installed to grade
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See attached tank integrity report by Olson's Sewer Service. MH installed to grade. See report.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 94 Decimal Feet
B. Periodically saturated soil/bedrock: 90 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Schirmers Percolation Testing, IncL394763-497-3566951 Katydid Lane NE Saint Michael, MN 55376NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: www.sptesting.wastewater@comcast.net

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #5988 (08/31/2020)

Charge Cost Quantity Total
Non-Taxable
added 08/31/2020 3:19 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 08/31/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantSteven Schirmers - 08/31/2020 3:21 PM - witnessed by Denise Lange
01c2bdccb9d555b0fd85ac8ab417251e
3490be1afe561072c419a5c3f66710c6
 
#1 Compliance Inspection AcceptedDenise Lange - 08/31/2020 3:21 PM
96f3b0dcb22519b55ca91c569b45a70e
c69c6d320a8c72211b339bed46aaf7c7
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by