Compliance Inspection Compliance Inspection Submission # Submission-2020-2517, UID # 30739
Status: System Replaced
 

System Status

System status on date: 10/05/2020 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
10027202300027390 ST CROIX TRL S, TOWN OF DENMARK7390ST CROIXTRLSHASTINGSTOWN OF DENMARK55033CARLSON FAITH M1980
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Comments/Explanation:
The tank was at normal operating level.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 11/28/1979

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 3.5 Decimal Feet
B. Periodically saturated soil/bedrock: 3.3 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #6130 (10/05/2020)

Charge Cost Quantity Total
Non-Taxable
added 10/05/2020 1:58 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 10/05/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 10/05/2020 1:58 PM
96672974313d48d2acf77437a35078c4
3f1d4fd46fb5bb91fce3892f61c681bc
 
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by