Compliance Inspection Compliance Inspection Submission # Submission-2020-2531, UID # 30872
Status: System Replaced
 

System Status

System status on date: 10/12/2020 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
2403221120025CITY OF FOREST LAKEHEIT CHRISTOPHER C & SHANNON71SYLVAN SHORES TERRACE2007
Property Owner's Mailing Address
(if different than property address):
20930 Keewahtin Ave N
Forest Lake MN 55025
Owner's representative:
Name:
Alex Pepin
Phone:
(612248 - 4281
Email:
alex.pepin@tenthirtyenvironmental.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined Tank Integrity Form (Attach)

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 07/01/1997

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 98.42 Decimal Feet
B. Periodically saturated soil/bedrock: 96.45 Decimal Feet
C. System separation: 1.96 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Ten Thirty Environmental Solutions, SBCL4082612-248-42811684 132nd Ave NE Blaine, MN 55449NoNoYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: alex.pepin@tenthirtyenvironmental.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #6152 (10/13/2020)

Charge Cost Quantity Total
Non-Taxable
added 10/13/2020 3:46 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 10/13/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantAlex Pepin - 10/13/2020 3:46 PM
77f5202d532e7dfb11662cc825e8265f
7dd57f3c63690179ac9e0f05f884932c
 
Text:
File(s):
    Text:
    3/31/22 SB - See attached letter mailed on accident regarding noncompliance. The system was replaced and properly abandoned in 2021 by connecting to the septic system in common ownership to the north (house) on PID2403221120026. Did not realize this until after mailing the letter; saving this correspondence in case homeowner calls.
    File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by