Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2465, Submission # Submission-2021-2647, UID # 32671
Status: System Replaced
 

System Status

System status on date: 02/01/2021 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
24029211300132735 LISBON AVE N, CITY OF LAKE ELMO2735LISBONAVENLAKE ELMOCITY OF LAKE ELMO55042WANGENSTEEN MARTIN & JOHNNA14HERITAGE FARM1997No
Owner's representative:
Name:
John Sievers
Phone:
(651485 - 6621
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Although not a compliance criteria, it should be noted that gravelless pipe is no longer approved for installation in the State
of Minnesota and we have had experience with this product having significantly reduced performance and/or life expectancy.
We cannot guarantee the performance of this system beyond the compliance date (2/1/2021).

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
Pinkys 2/1/2021

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No
Date of installation: 01/01/1997

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
See Report
A. Bottom of distribution media: 1.75 Decimal Feet
B. Periodically saturated soil/bedrock: 3.8 Decimal Feet
C. System separation: 2.1 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #6405 (02/05/2021)

Charge Cost Quantity Total
Non-Taxable
added 02/05/2021 1:27 PM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 02/08/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 02/05/2021 1:27 PM
946da75f6a4a0d5ebc023107c8f39949
fb71236ba95e0c6711a421402e1e9bce
 
#1 Compliance Inspection AcceptedTyler Dale - 03/03/2021 9:01 AM
3166e8aac4f70dd9e811bb20226d92a0
7c44cdd2fc7caf0a60b091cb0a7c1915
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by