SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2562, Submission # Submission-2021-2742, UID # 33506
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 04/23/2021 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes |
Comments/Explanation: | On wetter than normal springs this system may seep by looking at the moss bed over the drainfield but no seepage was detected on the day of inspection. House has been empty for months |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
Yes |
Sewage tank(s) leak below their designed operating depth: |
Yes |
Verification method(s): | Observed liquid level below operating depth Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | It is a 1964 system it is impossible for the tank to pass. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
Unknown |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 06/06/1964 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | Water was at 6 to 9 inches below grade at end of trench. Inspection port had water in it. |
A. Bottom of distribution media: | 1016.5 Decimal Feet |
B. Periodically saturated soil/bedrock: | .5 Decimal Feet |
C. System separation: | -1.5 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): | Mark J Hayes |
Inspector Email Address: | mngeoserv@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #6680 (04/27/2021)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 04/27/2021 11:33 AM $47 Flat Fee |
$42.00 | x 1 | $42.00 |
Grand Total | |||
Total | $42.00 | ||
Payment 04/27/2021 | $42.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Mark J. HAYES - 04/27/2021 11:36 AM 5946bb8a1ae5b51f91eea1ffa35e377d 20272ebdd1dfd1435cbba0fb54d464d9 | |
#1 Compliance Inspection Accepted | Tyler Dale - 04/28/2021 3:58 PM 1348b1346c767606ab25f534a29b4b04 2c63bee9b9285ce6a1da9ab4cbd0bfbe |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Tyler Dale | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Noncompliant |
Certificate of Compliance: |
Letter of Non-Compliance: |