Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2562, Submission # Submission-2021-2742, UID # 33506
Status: System Replaced
 

System Status

System status on date: 04/23/2021 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
140322034001414774 OAKHILL RD N, CITY OF SCANDIA14774OAKHILLRDNSCANDIACITY OF SCANDIA55073NOTCH BAILEY20COUNTY AUDITOR'S PLAT NO.61964
Owner's representative:
Name:
Tatyana Butkova
Phone:
(612808 - 9021
Email:
tbutkova@homesteadroad.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Comments/Explanation:
On wetter than normal springs this system may seep by looking at the moss bed over the drainfield but no seepage was detected on the day of inspection.  House has been empty for months

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Observed liquid level below operating depth
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
It is a 1964 system it is impossible for the tank to pass.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
Unknown
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/06/1964

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
Water was at 6 to 9 inches below grade at end of trench.  Inspection port had water in it.
A. Bottom of distribution media: 1016.5 Decimal Feet
B. Periodically saturated soil/bedrock: .5 Decimal Feet
C. System separation: -1.5 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Minnesota Geotechnical Services, LLCL3203320-980-6218PO Box 771 Maple Lake, MN 55358NoNoYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): Mark J Hayes
Inspector Email Address: mngeoserv@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #6680 (04/27/2021)

Charge Cost Quantity Total
Non-Taxable
added 04/27/2021 11:33 AM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 04/27/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantMark J. HAYES - 04/27/2021 11:36 AM
5946bb8a1ae5b51f91eea1ffa35e377d
20272ebdd1dfd1435cbba0fb54d464d9
 
#1 Compliance Inspection AcceptedTyler Dale - 04/28/2021 3:58 PM
1348b1346c767606ab25f534a29b4b04
2c63bee9b9285ce6a1da9ab4cbd0bfbe
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by