Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2658, Submission # Submission-2021-2881, UID # 34445
Status: Compliance Inspection Accepted
 

System Status

System status on date: 06/24/2021 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
060262012000212170 MORGAN AVE S, TOWN OF DENMARK12170MORGANAVESHASTINGSTOWN OF DENMARK55033DEBAERE PATRICK & JENNA2021
Owner's representative:
Name:
Mark Klem
Phone:
(651343 - 9117
Email:
sssepticsolutions@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/01/2010

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
Replacement system installed in 2010.  Mound with 3 tanks.  2' of good soil.
A. Bottom of distribution media: 1 Decimal Feet
B. Periodically saturated soil/bedrock: 2 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
SS Septic Solutions LLCL4137651-343-911714845 113th St S Hastings, MN 55033NoYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: sssepticsolutions@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #6960 (06/24/2021)

Charge Cost Quantity Total
Non-Taxable
added 06/24/2021 4:08 PM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 06/24/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantShelley L. Schlomka - 06/24/2021 4:08 PM
22976e6478f3b4e6135df2a4ad7a49b8
b0d5632e827eb3b72e630b2bcc162d8c
 
#1 Compliance Inspection AcceptedSarah Borrell - 07/08/2021 8:47 PM
61e1045a2248b44124ec463b4e072b10
3ba7a6a8f93ba37eee15cf74e3222b95
 
Inspection has been approved. All signatures have been obtained.
Text:
Change in use may require a permit.
File(s):
    Text:
    Inspection purpose is for reconstruction.
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by