SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2694, Submission # Submission-2021-2893, UID # 34667
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 06/25/2020 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined empty (pumped) tank(s) |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | b 1 1-4" top soil , 4-12" 10 yr 4/2silt loam, 12-30" silt loam with small rocks , 30-40"7.5 yr 4/4 loam with course gravel, 40-60" 7.5 yr 5/4 course gravel end bore |
A. Bottom of distribution media: | .24 Decimal Feet |
B. Periodically saturated soil/bedrock: | .6 Decimal Feet |
C. System separation: | .36 Decimal Feet |
D. Required compliance separation: | .36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): | Bob freiermuth |
Inspector Email Address: | bfsbob1@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #6991 (07/01/2021)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 07/01/2021 8:47 AM $47 Flat Fee |
$42.00 | x 1 | $42.00 |
Grand Total | |||
Total | $42.00 | ||
Payment 07/01/2021 | $42.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Bob Freiermuth - 07/21/2021 10:02 PM - witnessed by Sarah Borrell 3af0caf6befa52558ac464d3177af00d 9ede5991ad25cd899e84e612d29e65a3 | |
#1 Compliance Inspection Accepted | Sarah Borrell - 07/21/2021 10:02 PM 1e4ea5ea524133d342f2f62aa2c45696 8e7ed76de8f80845b8d576d2f2f99038 |
Inspection has been approved. All signatures have been obtained.
Text: | 6/25/2021 inspection per report. |
File(s): |
Text: | See update for complete report. |
File(s): |
Compliance Letter Type: | Certificate of Compliance | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Compliant |
Certificate of Compliance: |
Letter of Non-Compliance: |