Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2721, Submission # Submission-2021-2924, UID # 35008
Status: System Replaced
 

System Status

System status on date: 07/21/2021 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
02029214300035110 KIRKWOOD AVE N, CITY OF LAKE ELMO5110KIRKWOODAVENLAKE ELMOCITY OF LAKE ELMO55042LY ERIC & MAY Y LOR-LY31JESSE'S HIDEAWAY1978
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
The tank was pumped for the inspection. Lowered a camera into the empty tank - bottom, walls, cover and baffles appear ok. There is an 8" access pipe to grade, but no manhole cover was observed.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 10/02/1978

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 3 Decimal Feet
B. Periodically saturated soil/bedrock: 2.7 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7077 (07/21/2021)

Charge Cost Quantity Total
Non-Taxable
added 07/21/2021 1:42 PM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 07/21/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 07/21/2021 1:42 PM
b3c1af088ecca637c8c722d3808b503a
955626dff7f412e3c88cf28d379a346d
 
#1 Compliance Inspection AcceptedSarah Borrell - 07/28/2021 8:44 AM
0fbc2978234073cf73890836e7fbe4e2
9bf61e46d1e7aca06bdd2eaa00dd50e4
 
Inspection has been approved. All signatures have been obtained.
Text:
See #206 4.5.  If an existing sewage tank is to be used with the design of the new soil 
dispersal system, the tank must also be baffled, watertight, and the manhole cover brought 
to grade.
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by