Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2783, Submission # Submission-2021-2986, UID # 35674
Status: System Replaced
 

System Status

System status on date: 08/04/2021 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
28030211100018855 80TH ST N, CITY OF GRANT885580THSTNSTILLWATERCITY OF GRANT55082WEBER BONNIE K2021
Owner's representative:
Name:
Jim Vail
Phone:
(651464 - 2082
Email:
jim.vail@vailbuildersinc.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Comments/Explanation:
Home burned down.  Looking to rebuild and potentially reuse existing system.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Observed liquid level below operating depth
Comments/Explanation:
Tree roots observed below operating depth into tank.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 08/20/1987

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
Home burned down.  Looking to rebuild and potentially reuse existing system.  They cannot reuse existing system.  Already did design for replacement.  This documentation is for insurance purposes.  Nothing is currently discharging into the system as the home is no longer there.
A. Bottom of distribution media: 92.75 Decimal Feet
B. Periodically saturated soil/bedrock: 92.92 Decimal Feet
C. System separation: -0.17 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Ten Thirty Environmental Solutions, SBCL4082612-248-42811684 132nd Ave NE Blaine, MN 55449NoNoYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: alex.pepin@tenthirtyenvironmental.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7239 (08/19/2021)

Charge Cost Quantity Total
Non-Taxable
added 08/19/2021 3:08 PM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 08/19/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantAlex Pepin - 08/19/2021 3:08 PM
e55525beb0bbaded4f7f8dfba8239ba0
0941a96d5f26cde8109cd8780e35362b
 
#1 Compliance Inspection AcceptedSarah Borrell - 09/03/2021 12:22 PM
abc89d5e04f9749584516c2c11e338f7
acd1df91f82d826f42381f660fa544cf
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by