SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2783, Submission # Submission-2021-2986, UID # 35674
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 08/04/2021 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Comments/Explanation: | Home burned down. Looking to rebuild and potentially reuse existing system. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
Yes |
Verification method(s): | Observed liquid level below operating depth |
Comments/Explanation: | Tree roots observed below operating depth into tank. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 08/20/1987 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | Home burned down. Looking to rebuild and potentially reuse existing system. They cannot reuse existing system. Already did design for replacement. This documentation is for insurance purposes. Nothing is currently discharging into the system as the home is no longer there. |
A. Bottom of distribution media: | 92.75 Decimal Feet |
B. Periodically saturated soil/bedrock: | 92.92 Decimal Feet |
C. System separation: | -0.17 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | alex.pepin@tenthirtyenvironmental.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #7239 (08/19/2021)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 08/19/2021 3:08 PM $47 Flat Fee |
$42.00 | x 1 | $42.00 |
Grand Total | |||
Total | $42.00 | ||
Payment 08/19/2021 | $42.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Alex Pepin - 08/19/2021 3:08 PM e55525beb0bbaded4f7f8dfba8239ba0 0941a96d5f26cde8109cd8780e35362b | |
#1 Compliance Inspection Accepted | Sarah Borrell - 09/03/2021 12:22 PM abc89d5e04f9749584516c2c11e338f7 acd1df91f82d826f42381f660fa544cf |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Noncompliant |
Certificate of Compliance: |
Letter of Non-Compliance: |