Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2858, Submission # Submission-2021-3009, UID # 36038
Status: Compliance Inspection Accepted
 

System Status

System status on date: 09/01/2021 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
33030211200028765 68TH ST N, CITY OF GRANT876568THSTNSTILLWATERCITY OF GRANT55082KEYES JANET L & MARK W HATHERLY1976No
Owner's representative:
Name:
Jim Torseth
Phone:
(715579 - 2857
Email:
sssepticsolutions@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
Yes
: all 3
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
Tanks by the house were starting to cave in.  Rock and dirt in the tank.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
Yes
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
One manhole by house cracked and should be replaced when the new tanks go in.
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/01/1992

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2 Decimal Feet
B. Periodically saturated soil/bedrock: 5 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
SS Septic Solutions LLCL4137651-343-911714845 113th St S Hastings, MN 55033NoYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: sssepticsolutions@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7292 (09/01/2021)

Charge Cost Quantity Total
Non-Taxable
added 09/01/2021 6:53 AM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 09/01/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantShelley L. Schlomka - 09/29/2021 7:03 PM
73a5b4c850b764ef254a032b78a58438
8be0d66fefbfd5f81be12d3516b89327
 
#1 Compliance Inspection AcceptedSarah Borrell - 10/06/2021 2:42 PM
f308590241b6b71a3cda5f5328b1711a
3c79dfacd622e4fc0d26ec6b03cf3400
 
Inspection has been approved. All signatures have been obtained.
Text:
System #1 (1976 installation); west of home. After repairs made to inlet of tank, inspector then submitted a compliant report.  See 11/2021 report for details.
File(s):
    Text:
    See email to inspector regarding multiple SSTS on one property.
    File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by