Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2855, Submission # Submission-2021-3054, UID # 36396
Status: Compliance Inspection Accepted
 

System Status

System status on date: 09/23/2021 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
110302133000710077 101ST ST N, CITY OF GRANT10077101STSTNSTILLWATERCITY OF GRANT55082FITZMORRIS CHRIS R & BETH C23WOODLAND ACRES PLAT 21975
Owner's representative:
Name:
Chad Winter
Phone:
(123456 - 7890
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Two previous verifications (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
See Report
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7394 (09/26/2021)

Charge Cost Quantity Total
Non-Taxable
added 09/26/2021 2:25 PM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 09/26/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 09/26/2021 2:25 PM
d9bd77f4d2756a06a6a4a8a4a7ea1599
5d0bd0e452d5a26d8367a3dc2ba44706
 
#1 Compliance Inspection AcceptedSarah Borrell - 10/06/2021 1:34 PM
95c9a0e8a5cf26e82051108db05ed7ab
ba22a8e124bb7cce5539859463be3f30
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    10/6 - Per inspector on "laundry SSTS" in 2003 site map was just a straight pipe into a drainfield (no tank) and was removed after 2003 compliance inspection, which is why it is not included on the 2015 compliance inspection.
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance: