Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0647, Submission # Submission-2017-0712, UID # 3819
Status: Compliance Inspection Accepted
 

System Status

System status on date: 04/20/2017 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
20029204200092383 NORTHRIDGE AVENUE CT N, TOWN OF WEST LAKELAND2383NORTHRIDGE AVENUECTNSTILLWATERTOWN OF WEST LAKELAND55082MILLER LORIE W32CHRISTMAS RIDGE1995
Owner's representative:
Name:
Tom Trooien
Phone:
(612594 - 4496
Email:
tom.trooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/02/1995

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
0-16 sandy silt loam...10yr 3/3
16-35 silt loam...5yr 4/3
35-68 snady loam...7.5yr 5/4
2.5yr 5/8 concentrations @63"
A. Bottom of distribution media: 24 Decimal Feet
B. Periodically saturated soil/bedrock: 63 Decimal Feet
C. System separation: 39 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1500 & 1000 gallon septic tanks & 1,320 SF gravity , rock trench drainfield
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #1024 (06/26/2016)

Charge Cost Quantity Total
Non-Taxable
added 04/25/2017 10:35 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 04/25/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 04/27/2017 6:41 AM - witnessed by Kati Hallermann
aee905f376aed6abde291519ab46e089
28e1e2039c622e0c83bee295a56c86f1
 
#1 Compliance Inspection AcceptedKati Hallermann - 04/27/2017 6:41 AM
52e817bb66a4e7bebfa0aa3dee4bbe3a
ced2a425501ef8736fe461d1630c7d77
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance: