Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-2979, Submission # Submission-2022-3185, UID # 38915
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 12/22/2021 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Visual Inspection of the area. No signs of sewage to the ground surface. The renter did not report back-ups in to the house. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Tanks pumped and visually inspected with camera. No signs of cracks or leaking in any of the tanks. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Explain: | Sewage tanks, lids and baffles are in good condition. |
Date of Install
Date of install known: | Yes |
Date of installation: | 08/01/1994 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | See soil boring and site map for location of boring, tanks, and trenches. Note: The bottom of the distribution media is below the observed depth of the Periodic Saturated Soil level of 18". Also, effluent was observed above the expected level in the trenches. The system appears to be at the end of its useful life. |
A. Bottom of distribution media: | 24 Decimal Feet |
B. Periodically saturated soil/bedrock: | 18 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 24 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See soil boring log and site map for location of boring, tanks and trenches. |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): | Jesse Kloeppner |
Inspector Email Address: | jesse@ksd-mn.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #7691 (01/19/2022)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 01/19/2022 9:56 AM $47 Flat Fee |
$44.00 | x 1 | $44.00 |
Grand Total | |||
Total | $44.00 | ||
Payment 01/19/2022 | $44.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Jesse J. Kloeppner - 01/19/2022 9:56 AM 6ed08fb59226fc47382283ab48ae0051 70c0a3645f3c6d55117d1e397a1dc856 | |
#1 Compliance Inspection Accepted | Sarah Borrell - 01/20/2022 12:49 PM 388322b226948ee190e06c1ee762423d 6dada807cd4ebb1798579043210910fb |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Noncompliant |
Certificate of Compliance: |
Letter of Non-Compliance: |