SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3423, Submission # Submission-2022-3186, UID # 38916
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 01/17/2022 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Tanks visually inspected around the tanks. No sign of sewage. Homeowner did not report any sewage backups into the house. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined Tank Integrity Form (Attach) |
Comments/Explanation: | See attached Tank Integrity Form from Pinky's Sewer - MPCA Lic # 1673 |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Explain: | Pump in good working order. |
Date of Install
Date of install known: | Yes |
Date of installation: | 01/01/1996 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Other (See Comments/Explanation) |
Comments/Explanation: | See site plan and soil boring lots attached. |
A. Bottom of distribution media: | 1.5 Decimal Feet |
B. Periodically saturated soil/bedrock: | 5.2 Decimal Feet |
C. System separation: | 3.8 Decimal Feet |
D. Required compliance separation: | 2.6 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See site plan and soil boring lots attached. |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): | Jesse Kloeppner |
Inspector Email Address: | jesse@ksd-mn.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #7692 (01/19/2022)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 01/19/2022 10:27 AM $47 Flat Fee |
$44.00 | x 1 | $44.00 |
Grand Total | |||
Total | $44.00 | ||
Payment 01/19/2022 | $44.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Jesse J. Kloeppner - 01/19/2022 10:27 AM ff43bf8df01522cbb99ed21d27c4cdc7 890542c5df55c5b177fc34e1ed30c754 | |
#1 Compliance Inspection Accepted | Sarah Borrell - 01/06/2023 1:33 PM 6db13431bb7f75ee3b86ed42e264a05e 91426154ea356e213ef11f8455ac4ee2 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | Emailed Chad on 2/2 and 3/16 regarding status. See letter mailed 8/8/22. Both inspectors want to schedule time to meet onsite to resolve differences. 1/19/23 Contractor looking for records as they were contacted due to froze system. See communication under internal notes for property. |
File(s): |
|
Compliance Letter Type: | Certificate of Compliance | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Compliant |
Certificate of Compliance: |
Letter of Non-Compliance: |