Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3061, Submission # Submission-2022-3243, UID # 40063
Status: Compliance Inspection Accepted
 

System Status

System status on date: 03/23/2022 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
3502920310012295 QUANT AVENUE CT N, CITY OF LAKELAND295QUANT AVENUECTNLAKELANDCITY OF LAKELAND55043SMITH MATTHEW C132CROIXLAND ADD1973
Owner's representative:
Name:
Melissa White
Phone:
(123456 - 7890
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
See Report
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report. See attached revised tank integrity assessment.
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7851 (03/30/2022)

Charge Cost Quantity Total
Non-Taxable
added 03/30/2022 11:42 AM

$47 Flat Fee

$44.00 x 1 $44.00
Grand Total
Total $44.00
Payment 04/15/2022$44.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 03/30/2022 11:42 AM
de5f07f0891359437068670c2b2b0502
f0c6b3d930c433eb89f0aaabdea813c3
 
#1 Compliance Inspection AcceptedSarah Borrell - 04/18/2022 11:12 AM
88bd306d2549d5e6b8e6d803d2da159e
451a3eb3da7b807cb52d101920872777
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    4/18 (SB) per discussion with Inspector, Maintainer amended assessment as to what was intended which is the tank cover is sound but was difficult to remove and install due to warping of the plastic tank.
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance: