Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0259, Submission # Submission-2016-0299, UID # 4009
Status: Compliance Inspection Accepted
 

System Status

System status on date: 06/17/2016 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
3102920130012650 MIDWEST TRL N, TOWN OF WEST LAKELAND650MIDWESTTRLNLAKE ELMOTOWN OF WEST LAKELAND55042HEBERT STEPHEN D & LAURI J QUINN-HEBERT72EDEN LAKE ESTATES 2ND ADD1991
Owner's representative:
Name:
Jim Burns
Phone:
(612840 - 5522
Email:
septic@co.washington.mn.us

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/05/1981

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
0-19 loamy topsoil... 10yr 3/2
16-31 find sand... 10yr 4/4
31-48 silt loam... 7.5yr 4/6
48-76 sand... 10yr 5/4
redox @68" concentration... 5yr 6/8
A. Bottom of distribution media: 36 Decimal Feet
B. Periodically saturated soil/bedrock: 68 Decimal Feet
C. System separation: 32 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1,500 gallon septic tank & rock trench drainfield
Attach Files:

Certification

Inspector:
Inspector Email Address: tom.trooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #1094 (07/13/2016)

Charge Cost Quantity Total
Non-Taxable
added 07/13/2016 8:32 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 07/13/2016$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 07/13/2016 8:33 PM - witnessed by Kati Hallermann
2b84ae826a6e99f9f48d15fcd7a81709
1c026974410ff71ebdf2056684c61f91
 
#1 Compliance Inspection AcceptedKati Hallermann - 07/13/2016 8:33 PM
ca399fd772eb6f1ac26eb59ed8b1f93f
44182f6d75cd578ba6f35bbfa5b50306
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by