Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0260, Submission # Submission-2016-0300, UID # 4010
Status: Compliance Inspection Accepted
 

System Status

System status on date: 06/25/2016 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
340292032000815062 HUDSON BLVD N, TOWN OF WEST LAKELAND15062HUDSONBLVDNSTILLWATERTOWN OF WEST LAKELAND55082KAYNES JUSTIN S & HEATHE M1960
Owner's representative:
Name:
Tom Trooien
Phone:
(612594 - 4496
Email:
tom.trooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 07/01/1995

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
0-4 loamy topsoil... 10 yr 3/2
4-38 med sand... 7.5yr 4/6
38-66 gravelly sand... 10yr 4/6
A. Bottom of distribution media: 36 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 32 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
2 1,000 gallon septic tanks & gravity, rock trench drainfield
Attach Files:

Certification

Inspector:
Inspector Email Address: tom.trooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #1095 (07/13/2016)

Charge Cost Quantity Total
Non-Taxable
added 07/13/2016 8:55 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 07/13/2016$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 07/13/2016 8:57 PM - witnessed by Kati Hallermann
b3668a80a4053de06b7c7b88be10f155
3003bd678921d44e2ec3cba2d36d409e
 
#1 Compliance Inspection AcceptedKati Hallermann - 07/13/2016 8:57 PM
2c9612f984e73ae7487d21c33a000882
bed71ed13c39beb8ddd04ff7e5cc0785
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by