Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3036, Submission # Submission-2022-3248, UID # 40239
Status: System Replaced
 

System Status

System status on date: 03/30/2022 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
22029212200092909 JAMLEY AVE N, CITY OF LAKE ELMO2909JAMLEYAVENLAKE ELMOCITY OF LAKE ELMO55042CHINN LARRY R & DEBORAH J1956
Owner's representative:
Name:
Jeanine Berfeldt
Phone:
(651485 - 5460
Email:
jberfeldt@yahoo.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
Yes
: 1
Verification method(s):
Examined empty (pumped) tank(s)

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2.3 Decimal Feet
B. Periodically saturated soil/bedrock: 5.3 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
David R. BrownL3649651-788-3296PO Box 251026 Woodbury, MN 55125NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: drufusb1@yahoo.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7869 (03/31/2022)

Charge Cost Quantity Total
Non-Taxable
added 03/31/2022 7:50 AM

$47 Flat Fee

$44.00 x 1 $44.00
Grand Total
Total $44.00
Payment 03/31/2022$44.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantDavid R. Brown - 03/31/2022 7:50 AM
a81df4d1e21494bf278ef57b6c4861c1
93fde409f50fdd828dd906a319d3c307
 
#1 Compliance Inspection AcceptedSarah Borrell - 04/06/2022 8:31 AM
b40b73333425cbb92fe03e13631d0c39
a9baca70d8e02d057aeaa5e41f421640
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by