Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3046, Submission # Submission-2022-3262, UID # 40445
Status: System Replaced
 

System Status

System status on date: 04/11/2022 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
15029213300389181 31ST ST N, CITY OF LAKE ELMO918131STSTNLAKE ELMOCITY OF LAKE ELMO55042JABB LLCIFARMS OF LAKE ELMO1965
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
: both
Verification method(s):
Probed tank(s) bottom
Examined empty (pumped) tank(s)
Comments/Explanation:
The tanks were pumped during the inspection. Probed the bottoms and lowered a camera into the empty tanks. The tanks are of block construction with no outlet on the 2nd tank. The tank bottoms are approximately 12 feet below grade. No drainfield located.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Not applicable (Holding tank(s), no drainfield)
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7905 (04/11/2022)

Charge Cost Quantity Total
Non-Taxable
added 04/11/2022 5:59 PM

$47 Flat Fee

$44.00 x 1 $44.00
Grand Total
Total $44.00
Payment 04/11/2022$44.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 04/11/2022 5:59 PM
ef986ca54144308a80859f8499b98aac
85389dd1fbeff0ec19e890a69e868084
 
#1 Compliance Inspection AcceptedSarah Borrell - 04/13/2022 8:58 AM
0e95df64cde3b163a6e553dee6ffff75
dc0990e125ca409ebc3b065b694c28e2
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant