Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3047, Submission # Submission-2022-3265, UID # 40454
Status: System Replaced
 

System Status

System status on date: 04/07/2022 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
15030212100139475 96TH ST N, CITY OF GRANT947596THSTNWHITE BEAR LAKECITY OF GRANT55110BENNETT JUSTIN C & AMY A61VICTORIA STATION NO.31997
Owner's representative:
Name:
Ken Wohlferd
Phone:
(612383 - 6861
Email:
kenneth_wohlferd@comcast.net

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Visual Inspection of the area. No signs of sewage to the ground surface.  The homeowners did not report back-ups in the house.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Tanks pumped and visually inspected with camera. No signs of cracks or leaking in any of the tanks.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 04/24/1984

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
Periodically saturated soil/bedrock observed. Trench depth verified by digging to outlet pipe of Distribution Box.
A. Bottom of distribution media: 93.2 Decimal Feet
B. Periodically saturated soil/bedrock: 92.7 Decimal Feet
C. System separation: .5 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See attached soil boring logs and site plan location of trenches and borings.
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
SELF/OTHERn/an/an/a
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): Jesse Kloeppner
Inspector Email Address: jesse@ksd-mn.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7912 (04/12/2022)

Charge Cost Quantity Total
Non-Taxable
added 04/12/2022 7:41 PM

$47 Flat Fee

$44.00 x 1 $44.00
Grand Total
Total $44.00
Payment 04/12/2022$44.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantJesse J. Kloeppner - 04/12/2022 7:41 PM
d073f9ee57301e320185ecd29a7319fb
4516aeac3191ec3f8ef46155583f7fdc
 
#1 Compliance Inspection AcceptedSarah Borrell - 04/13/2022 9:16 AM
877f9324bd2364f1a0bf92dd1302bdc6
04a1021d5d8f24845ee8a7c9337b60f9
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by