Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0275, Submission # Submission-2016-0315, UID # 4080
Status: System Replaced
 

System Status

System status on date: 06/17/2016 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
24030214100068400 MANNING AVE N, CITY OF GRANT8400MANNINGAVENSTILLWATERCITY OF GRANT55082HURLEY TIMOTHY & STEPHANIE1981
Owner's representative:
Name:
Carolyn Gronfield
Phone:
(763591 - 6046
Email:
septic@co.washington.mn.us

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
0-16 loamy topsoil...10yr 3/2
16-31 find sand... 10yr 4/4
31-48 silt loam... 7.5yr 4/6
48-72 sand... 10yr 5/4 Redox@36" depletions 2.5yr 5/6
A. Bottom of distribution media: 36 Decimal Feet
B. Periodically saturated soil/bedrock: 36 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1,500 gallon septic tank & rock trench drainfield
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #1120 (07/16/2016)

Charge Cost Quantity Total
Non-Taxable
added 07/16/2016 10:15 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 07/16/2016$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantCw6463L1 - 07/21/2016 8:57 AM - witnessed by Christopher W. LeClair REHS
4e4bc89524cb415b2f2dc71377196761
abc38139b29663c4a9405c5d049cb6c4
 
#1 Compliance Inspection AcceptedChristopher W. LeClair REHS - 07/21/2016 8:57 AM
48fe2ed4a32403fabe110619bc0349ad
513b00f898186c1c42fb06c9abf64dee
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
        Powered by