SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3267, Submission # Submission-2022-3488, UID # 42147
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 07/28/2022 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Homeowner testimony (See Comments/Explanation) |
Comments/Explanation: | See attached report. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined Tank Integrity Form (Attach) |
Comments/Explanation: | See attached report. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 09/10/1992 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 97.5 Decimal Feet |
B. Periodically saturated soil/bedrock: | 95.2 Decimal Feet |
C. System separation: | 2.3 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | benzierke@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #8370 (08/02/2022)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 08/02/2022 12:59 PM $47 Flat Fee |
$44.00 | x 1 | $44.00 |
Grand Total | |||
Total | $44.00 | ||
Payment 08/02/2022 | $44.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Benjamin J. Zierke - 08/02/2022 12:59 PM 3ed92cf55226ff9b98164d7d03e4ba62 50cc88e2b006610532370571ef04788f | |
#1 Compliance Inspection Accepted | Sarah Borrell - 08/03/2022 12:44 PM 190cf68c271b7dd15308ad2cd47461be 26afe567b0105c2ddbbc1582314f8aab |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | 1/3/2023 SB - spoke with a potential buyer. He wanted to know if existing system would be compliant with 4 bedrooms. No, sized for 3 bedrooms. Went thru Section 6.2. He asked if he would need to add on to ssts if they went from a full bathroom upstairs to two, 3/4 bathrooms upstairs. This would not likely require upgrades as this shouldn't affect water use, but system would need to be both adequate and conforming. He also asked if they just added an egress window and a murphy bed to basement if they needed to add on to ssts. Advised him to consult with local building inspector and referenced bedroom definition in #206. |
File(s): |
Compliance Letter Type: | Certificate of Compliance | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Compliant |
Certificate of Compliance: |
Letter of Non-Compliance: |