Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3309, Submission # Submission-2022-3521, UID # 42687
Status: System Replaced
 

System Status

System status on date: 09/01/2022 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
11028201301111420 QUINLAN AVE S, CITY OF LAKE ST CROIX BEACH1420QUINLANAVESLAKELANDCITY OF LAKE ST CROIX BEACH55043BAUER KARIN ETAL24ALTON ESTATES1991
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
Yes
: septic tank
Verification method(s):
Probed tank(s) bottom
Examined construction records
Observed liquid level below operating depth
Comments/Explanation:
The tank, which is partially covered by a concrete patio, was below normal operating level, the cover is cracked, the outlet is crumbling and the outlet baffle is detached.
The tank was determined to be non-compliant, therefore it was not pumped for the inspection.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 10/01/1991

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2.8 Decimal Feet
B. Periodically saturated soil/bedrock: 6 Decimal Feet
C. System separation: 3.2 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #8462 (09/01/2022)

Charge Cost Quantity Total
Non-Taxable
added 09/01/2022 10:59 AM

$47 Flat Fee

$44.00 x 1 $44.00
Grand Total
Total $44.00
Payment 09/01/2022$44.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 09/01/2022 10:59 AM
7b85ba92b3e4083eb1970ed251c47f4b
b2d272ff94589fc3d07bf6c6cd85f04a
 
#1 Compliance Inspection AcceptedTyler Dale - 09/28/2022 2:23 PM
5332f31f6995efb0aa8a8dbf52213571
f18fccd7fecc19b50bb8031a852339b1
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by