Compliance Inspection Compliance Inspection Compliance Inspection # CI-2022-3364, Submission # Submission-2022-3575, UID # 43395
Status: Compliance Inspection Accepted
 

System Status

System status on date: 09/21/2022 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
270272033001510909 PARIS AVE S, TOWN OF DENMARK10909PARISAVESHASTINGSTOWN OF DENMARK55033ERICKSON ANGELA M & JEREMIAH81MYSTIC RIVER RIDGE1993
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined construction records
Examined empty (pumped) tank(s)
Comments/Explanation:
The maintenance hole covers are buried 1.5' below grade and the owner refused to expose the covers. See attached signed statement by the owner refusing to allow the removal of solids and liquids through the maintenance hole. The tanks were at normal operating level, then were pumped through the pumping pipe for the inspection. Lowered a camera into the empty tanks - bottoms, walls, covers, baffles, risers and maintenance hole covers ok

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 12/10/1993

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2.7 Decimal Feet
B. Periodically saturated soil/bedrock: 4.9 Decimal Feet
C. System separation: 2.2 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #8597 (10/11/2022)

Charge Cost Quantity Total
Non-Taxable
added 10/11/2022 6:47 PM

$47 Flat Fee

$44.00 x 1 $44.00
Grand Total
Total $44.00
Payment 10/11/2022$44.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 10/11/2022 6:47 PM
1de312b61de28ba084ed365fea098059
ef2017b9a0a591718d1b2e86454357c7
 
#1 Compliance Inspection AcceptedSarah Borrell - 11/17/2022 9:16 AM
6620b7b6b68769dd351103b4510886b3
97942076974b1875376e96dad33b86fa
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance: