Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3505, Submission # Submission-2023-3711, UID # 46163
Status: System Replaced
 

System Status

System status on date: 05/11/2023 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
23030214400048140 LAKE ELMO AVE N, CITY OF GRANT8140LAKE ELMOAVENSTILLWATERCITY OF GRANT55082LEE KIRBY & LINDSAY EASTMAN31BANKER ESTATES1991
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
Opened the maintenance hole cover for pumping & inspecting. The tank was at normal operating level, then was pumped & back-flushed. Performed a visual inspection & lowered a light & camera into the empty tank - bottom, walls, cover, baffles, riser & maintenance hole cover ok.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No
Date of installation: 11/16/1990

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2.6 Decimal Feet
B. Periodically saturated soil/bedrock: 3.3 Decimal Feet
C. System separation: .7 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #9064 (05/11/2023)

Charge Cost Quantity Total
Non-Taxable
added 05/11/2023 8:59 AM

$47 Flat Fee

$45.00 x 1 $45.00
Grand Total
Total $45.00
Payment 05/11/2023$45.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 05/11/2023 8:59 AM
bc82ef7a019b3c4cc277678eda00b4e3
a8fa57ceacc305d892c54ea17122fbd1
 
#1 Compliance Inspection AcceptedSarah Borrell - 05/26/2023 2:57 PM
d68ee538147262d67d106eb5d05b14ca
148e8deef44d88983e7d0704f1110c22
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance: