Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3518, Submission # Submission-2023-3723, UID # 46221
Status: System Replaced
 

System Status

System status on date: 05/15/2023 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Impact on Public Health (Compliance Component #1) - Imminent threat to public health and safety
Tank Integrity (Compliance Component #2) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
010302113000311575 LOCKRIDGE AVE N, CITY OF GRANT11575LOCKRIDGEAVENSTILLWATERCITY OF GRANT55082MEYER AMBER D & DAVID L31BROWN'S CREEK ESTATES1987
Property Owner's Mailing Address
(if different than property address):
11575 Lockridge Ave N
Grant MN 55082
Owner's representative:
Name:
Kristin Scholl
Email:
kristen33@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
Yes System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Comments/Explanation:
Upslope Trench(s) observed to be discharging to surface

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
Yes
: Septic
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
Lineal crack(s) observed on floor.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 01/01/1987

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Other (See Comments/Explanation)
Comments/Explanation:
Due to other deficiencies in the existing SSTS (Discharging to Surface, Tank Integrity) no Soil Data will be submitted @ this time.
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See REVISED report (REV1)
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Progressive Onsite Septic LLCL4145763-350-020625713 4th St W Apt 312 Zimmerman, MN 55398NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: bill@pos-mn.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #9073 (05/19/2023)

Charge Cost Quantity Total
Non-Taxable
added 05/19/2023 7:52 AM

$47 Flat Fee

$45.00 x 1 $45.00
Grand Total
Total $45.00
Payment 05/19/2023$45.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantWilliam G. Hetzler - 05/19/2023 7:52 AM
1ce0bc7b3083883cb6f8051e8e6884b7
bf34cb5968560dac38ffb117fa6caee0
 
#1 Compliance Inspection AcceptedSarah Borrell - 06/12/2023 2:14 PM
415cf6609605712e4cb024b5602dbe01
9622ea77a66d7863883f27ce1facad69
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    It is expected that the inspector completes all compliance components and does not stop once they find something that is noncompliant. According to Bill as of 6/6 he is working on amendments.  Revision submitted 6/7/23 & uploaded 6/12/23
    File(s):
    Compliance Letter Type: Imminent Threat, Abatement Notice and Order Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by